Realignment of myocardial first-pass MR perfusion images using an automatic detection of the heart-lung interface
2004
International audience; Abstract: Magnetic resonance first-pass imaging of a bolus of contrast agent is well adapted to distinguish normal and hypoperfused areas of the myocardium. In most cases, the signal intensity-time curves in user defined regions of interest (ROI) are studied. As image acquisition is ECG-gated, the images are acquired at the same moment in the cardiac cycle, and the basic shape of the heart is similar from one view to the next. However, superficial respiratory motion can displace the heart in the short-axis plane. The aim of this study is to correct for the respiratory motion of the heart by performing an automatic realignment of the myocardial ROI based on a method t…
Automatic fuzzy classification of the washout curves from magnetic resonance first-pass perfusion imaging after myocardial infarction.
2005
International audience; Abstract: Objectives: We sought to investigate the diagnostic ability of cardiac magnetic resonance imaging (MRI) perfusion in acute reper-fused myocardial infarction. The study used fuzzy logic to automatically classify signal intensity-time curves from myocardial segments into 3 categories: normal, hypointense, and Hyperintense. Materials and Methods: Thirty-eight patients with myocardial infarction underwent short-axis cine-MRI and contrast-enhanced MRI to provide data on wall thickening and the transmural extent of infarction. Of these, 17 had a second cardiac MRI to ascertain the functional recovery in each segment. Results: The fuzzy logic based classification …